An uninterruptible power supply can keep equipment supplied while the facility transitions to another source or addresses a brief power disturbance. It is one component of a larger power chain. A useful underwriting review follows each UPS and its maintenance bypass through the batteries, distribution, and downstream racks. Confirm which halls share hardware, protective functions or control infrastructure. DOE’s data center design guide
Identify how redundancy behaves during maintenance
A standby path may be present but unavailable during a concurrent upgrade. A bypass can also change what protection the load receives. Obtain a qualified engineer’s description of the accepted arrangement, the permitted maintenance windows, and expected service availability for each affected rack or hall. Verify that operational estimates include critical support loads where appropriate.
Example of temporary loss with uncertain damage
A facility experiences a utility disturbance while one UPS path is unavailable. Some tenant equipment loses power. Operators later return the campus electrical systems to use without major repair, while individual tenants report component damage and service credits. Confirm what physically failed, which property was affected, who owns it, and what the outage and repair records actually show. An equipment breakdown policy, property income form, and liability contract can all use different triggers. Compare the interruption and underlying cause separately from alleged damage to customer property, and review the insured interests and contract limits in each case.
Evidence to obtain before renewal
- Current power drawings, accepted load and battery capacity estimates, and monitoring and maintenance records.
- An assessment of each bypass or shared dependency, including which halls are exposed during a scheduled maintenance window.
- Tenant agreements, ownership schedules and evidence of replacement and service capability.
- Chronology of any event, including contractor and vendor involvement.

Validate the usable support behind the service promise
For underwriting, have the responsible engineer define the available UPS protection for each affected load during its normal configuration and during maintenance. Document the accepted battery health assumptions and test records at the actual site. A load move, new cooling device, or tenant expansion can change the scope of what the equipment supports. Identify whether the customer owns downstream power equipment or depends on the facility owner for maintenance response. Review the contract's service window and agreed notice procedure with actual uptime reporting, including which calendar measure applies to a utility incident.
Give the adjuster a clean separation of loss categories
A campus may claim its own damaged power hardware and interruption, while tenants allege damage to computing equipment or lost processing service. Vendor findings and time-stamped records can distinguish an orderly protective action, a machinery failure and an effect that persists after the UPS recovers. Confirm ownership, custody or liability protections before assigning equipment claims to the owner's policy. Compare deductibles and the actual scope of breakdown, property income or liability coverage, including how business income is affected if only a portion of the campus loses service. Tenant credits may still be owed if reviewed contractually even when a distinct insurance trigger is not satisfied.
When estimating loss, record whether the hall was already under a planned outage, what capacity would have been available without the incident, and which costs reasonably restored service. Retain approved incident communications, operator logs, ownership schedules and specialist reports.